- Breaking News Related to Macular Degeneration, Cataract, Glaucoma, Corneal Disease and Other Eye Conditions - http://eyedocnews.com -
Dr. Masket Describes Fix To Negative Dysphotopsia
Posted By Dr. Ari Weitzner On October 10, 2011 @ 5:07 am In Cataract | Comments Disabled
Negative dysphotopsia [1] has been addressed at EyeDocNews- it’s when patients notice a dark crescent in their peripheral visual field, due to the edge of the implant. For reasons I am still not clear, the culprit is the way the anterior capsule covers the IOL edge. Dr. Masket advises a pretty simple fix- tease the IOL off the anterior capsule with a blunt instrument, and cause reverse optic capture with the optic on top of the anterior capsule, and the haptics still in the bag. A lot easier than IOL exchange.
Article printed from Breaking News Related to Macular Degeneration, Cataract, Glaucoma, Corneal Disease and Other Eye Conditions: http://eyedocnews.com
URL to article: http://eyedocnews.com/006143-dr-masket-desribes-fix-to-negative-dysphotopsia/
URLs in this post:
[1] Negative dysphotopsia: http://eyedocnews.com/005987-iol-exchange-iris-fixation-suture-does-not-resolve-postop-negative-dysphotopsia/